Sensor (Order No.) | Lower Corner Freq. | Upper Corner Freq. | Precision | Current Range | Primary Connection | LMG670 | LMG500 | LMG450 |
LMG95 LMG95e |
Typical Applications |
L60-Z406 | 5Hz | 50kHz | 0.20 % | 40A | Clamp-On | x | - | - | - | Frequency Inverter Output |
L60-Z60 | 30Hz | 10kHz | 0.50% | 1000A | x | - | - | - | General Purpose | |
L60-Z66 | 30Hz | 10kHz | 0.50% | 3000A | x | - | - | - | General Purpose | |
L60-Z68 | DC | 2kHz | 2.00% | 1000A | x | - | - | - | DC-Clamp | |
LMG-Z322 | 30Hz | 10kHz | 0.50 % | 1000A | x | x | x | x | General Purpose | |
LMG-Z329 | 40Hz | 5kHz | 0.50 % | 3000A | x | x | x | x | General Purpose | |
LMG-Z406 | 5Hz | 50kHz | 0.20 % | 40A | - | x | x | x | Frequency Inverter Output | |
L45-Z10 | 2Hz | 40kHz | 0.15 % | 1000A | - | x | x | x | Frequency Inverter Output | |
L45-Z16 | 5Hz | 10kHz | 0.15 % | 3000A | - | x | x | x | Frequency Inverter Output | |
L45-Z26 | DC | 2kHz | 1.60 % | 1000A | - | x | x | x | DC-Clamp |
Sensor (Order No.) | Lower Corner Freq. | Upper Corner Freq. | Precision | Current Range | Primary Connection | LMG670 | LMG500 | LMG450 |
LMG95 LMG95e |
Typical Applications |
L45-Z32-Flex500 | 10Hz | 5kHz | 6.10 % | 500A | Flexible Clamp-On | - | x | x | x | 50Hz Power Quality, for difficult access Areas |
L45-Z32-Flex1000 | 10Hz | 5kHz | 3.10 % | 1000A | - | x | x | x | ||
L45-Z32-Flex3000 | 10Hz | 5kHz | 3.10 % | 3000A | - | x | x | x |
Sensor (Order No.) | Lower Corner Freq. | Upper Corner Freq. | Precision | Current Range | Primary Connection | LMG670 | LMG500 | LMG450 |
LMG95 LMG95e |
Typical Applications |
L45-Z28-Hall50 | DC | 200kHz | 0.90 % | 50A | Clamp-On | - | x | x | x | Frequency Inverter Output, Frequency Inverter DC Link, Low Cost |
L45-Z28-Hall100 | DC | 200kHz | 0.70 % | 100A | - | x | x | x | ||
L45-Z28-Hall200 | DC | 100kHz | 0.65 % | 200A | - | x | x | x | ||
L45-Z29-Hall300 | DC | 100kHz | 0.40 % | 300A | - | - | x | - | ||
L45-Z29-Hall500 | DC | 100kHz | 0.80 % | 500A | - | - | x | - | ||
L45-Z29-Hall1000 | DC | 150kHz | 0.40 % | 1000A | - | - | x | - | ||
L45-Z29-Hall2000 | DC | 100kHz | 0.30 % | 2000A | - | - | x | - | ||
L50-Z29-Hall300 | DC | 100kHz | 0.40 % | 300A | - | x | - | x | ||
L50-Z29-Hall500 | DC | 100kHz | 0.80 % | 500A | - | x | - | x | ||
L50-Z29-Hall1000 | DC | 150kHz | 0.4 % | 1000A | - | x | - | x | ||
L50-Z29-Hall2000 | DC | 100kHz | 0.3 % | 2000A | - | x | - | x | ||
Hall100-L6 | DC | 100kHz | ±0.5 % | 100A | x | - | - | - | ||
Hall300-L6 | DC | 100kHz | ±0.5 % | 300A | x | - | - | - | ||
Hall500-L6 | DC | 100kHz | ±0.5 % | 500A | x | - | - | - | ||
Hall1000-L6 | DC | 100kHz | ±0.5 % | 1000A | x | - | - | - | ||
Hall2000-L6 | DC | 100kHz | ±0.5 % | 2000A | x | - | - | - |
Sensor (Order No.) | Lower Corner Freq. | Upper Corner Freq. | Precision | Current Range | Primary Connection | LMG670 | LMG500 | LMG450 |
LMG95 LMG95e |
Typical Applications |
L95-Z06 / L95-Z06HV | 5kHz | 500kHz | 0.50 % | 15A | 4mm sockets / wire | x | x | x | x | Summing Current Transducer, Lighting Applications, Ultrasonic |
Sensor (Order No.) | Lower Corner Freq. | Upper Corner Freq. | Precision | Current Range | Primary Connection | LMG670 | LMG500 | LMG450 |
LMG95 LMG95e |
Typical Applications |
L95-SHxxx | DC | 100kHz | 0.15 % |
selectable uA-1A |
4mm sockets | x | x | - | x | Very Low Current |
L95-SHxxxP | DC | 10kHz |
0.15% 0.30 % |
selectable uA-0.5A |
x | x | - | x | 50Hz Standby Current, Overload Protection 20A |